Analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles

This paper compares the thermodynamic properties, of saturated and superheated water, computed with proposed correlations of two groups of authors versus those obtained by the IAPWS. Besides, the COP of an absorption refrigeration cycle using  as working pair, is estimated, for different effectiven...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Rodríguez Muñoz, José Luis, Valencia Castillo, César Manuel, Pacheco Cedeño, José Sergio, Noh Pat, Felipe, Borja Soto, Carlos Ernesto
Formato: Online
Lenguaje:spa
Publicado: Universidad Autónoma de Baja California 2023
Acceso en línea:https://recit.uabc.mx/index.php/revista/article/view/263
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id recit-article-263
record_format ojs
institution RECIT
collection OJS
language spa
format Online
author Rodríguez Muñoz, José Luis
Valencia Castillo, César Manuel
Pacheco Cedeño, José Sergio
Noh Pat, Felipe
Borja Soto, Carlos Ernesto
spellingShingle Rodríguez Muñoz, José Luis
Valencia Castillo, César Manuel
Pacheco Cedeño, José Sergio
Noh Pat, Felipe
Borja Soto, Carlos Ernesto
Analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles
author_facet Rodríguez Muñoz, José Luis
Valencia Castillo, César Manuel
Pacheco Cedeño, José Sergio
Noh Pat, Felipe
Borja Soto, Carlos Ernesto
author_sort Rodríguez Muñoz, José Luis
title Analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles
title_short Analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles
title_full Analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles
title_fullStr Analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles
title_full_unstemmed Analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles
title_sort analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles
description This paper compares the thermodynamic properties, of saturated and superheated water, computed with proposed correlations of two groups of authors versus those obtained by the IAPWS. Besides, the COP of an absorption refrigeration cycle using  as working pair, is estimated, for different effectiveness of the solution heat exchanger, using such correlations. The results show that there is a good agreement between both correlations proposed in comparison with the IAPWS formulations. When the correlations are used to compute the COP of the cycle, those correlations proposed by one of the two groups of authors estimate it very well, being  the maximum deviation when the cycle operates at  of solution heat exchanger effectiveness; while if the proposed correlations by the other group of authors are used, the deviation is almost constant averaging . Finally, the advantage of using the correlations proposed by both authors, in comparison with those obtained by the IAPWS formulations, is that these result from simple polynomials correlations (n≤6), which makes them easier to program, as well as their possible implementation as a computational tool for the calculation of water properties in the analysis and simulation of absorption refrigeration systems.
publisher Universidad Autónoma de Baja California
publishDate 2023
url https://recit.uabc.mx/index.php/revista/article/view/263
_version_ 1792095383378198528
spelling recit-article-2632024-02-13T02:55:52Z Analysis of thermodynamics properties correlations for saturated and superheated water applied in absorption refrigeration cycles Análisis de correlaciones para propiedades termodinámicas del agua saturada y vapor sobrecalentado aplicado a ciclos de refrigeración por absorción Rodríguez Muñoz, José Luis Valencia Castillo, César Manuel Pacheco Cedeño, José Sergio Noh Pat, Felipe Borja Soto, Carlos Ernesto Correlaciones Refrigeración por absorción LiBr-H2O SHX COP Correlations Absorption refrigeration LiBr-H2O SHX COP This paper compares the thermodynamic properties, of saturated and superheated water, computed with proposed correlations of two groups of authors versus those obtained by the IAPWS. Besides, the COP of an absorption refrigeration cycle using  as working pair, is estimated, for different effectiveness of the solution heat exchanger, using such correlations. The results show that there is a good agreement between both correlations proposed in comparison with the IAPWS formulations. When the correlations are used to compute the COP of the cycle, those correlations proposed by one of the two groups of authors estimate it very well, being  the maximum deviation when the cycle operates at  of solution heat exchanger effectiveness; while if the proposed correlations by the other group of authors are used, the deviation is almost constant averaging . Finally, the advantage of using the correlations proposed by both authors, in comparison with those obtained by the IAPWS formulations, is that these result from simple polynomials correlations (n≤6), which makes them easier to program, as well as their possible implementation as a computational tool for the calculation of water properties in the analysis and simulation of absorption refrigeration systems. El presente trabajo compara las propiedades termodinámicas, del agua saturada y sobrecalentada, obtenidas mediante correlaciones propuestas por dos grupos de autores contra aquellas correlaciones obtenidas por la IAPWS. Además, el COP de un ciclo de refrigeración por absorción es estimado, en el que  es empleado como mezcla de trabajo, para distintas efectividades del intercambiador de calor de solución, mediante el uso de dichas correlaciones. Los resultados muestran que, al comparar las propiedades, estimadas por medio de las correlaciones propuestas, contra las obtenidas por la IAPWS, se concluye que hay una buena concordancia entre la mayoría de propiedades bajo estudio. Cuando se utilizan las correlaciones para estimar el COP del ciclo, las correlaciones propuestas por uno de los dos grupos de autores lo estiman muy bien, siendo la máxima desviación de  cuando la efectividad del intercambiador de calor de solución es de ; mientras que, si se utilizan las correlaciones propuestas por el otro grupo de autores, la desviación es casi constante, promediando . Finalmente, una ventaja del uso de las correlaciones propuestas por ambos autores, en comparación con las obtenidas por la IAPWS, es que estas resultan de formulaciones de simples polinomios (n 6), lo que las hace más sencillas de programar, así como su posible implementación como herramienta computacional para el cálculo de las propiedades del agua durante el análisis y simulación de sistemas de refrigeración por absorción. Universidad Autónoma de Baja California 2023-10-02 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion application/pdf text/html application/zip https://recit.uabc.mx/index.php/revista/article/view/263 10.37636/recit.v6n4e263 REVISTA DE CIENCIAS TECNOLÓGICAS; Vol. 6 No. 4 (2023): October-December; e263 REVISTA DE CIENCIAS TECNOLÓGICAS; Vol. 6 Núm. 4 (2023): Octubre-Diciembre; e263 2594-1925 spa https://recit.uabc.mx/index.php/revista/article/view/263/475 https://recit.uabc.mx/index.php/revista/article/view/263/476 https://recit.uabc.mx/index.php/revista/article/view/263/477 Copyright (c) 2023 José Luis Rodríguez Muñoz, Cesar Manuel Valencia Castollo, José Sergio Pacheco Cedeño, Felipe Noh Pat, Carlos Ernesto Borja Soto https://creativecommons.org/licenses/by/4.0